Cyberpower Datacenter UPS Systems OLS3S20KE

CyberPower

UPS 3Ph-400VAC/1Ph-230VAC input, 1Ph 230VAC Output, LCD Control Panel, Tower Model, 20000VA/18000W, Double Conversion Online, 1 x hardwire terminal block outlet, BUT 6 mins @ full-load, Genset Compatible, Surge Protection 445 Joules, PowerPanel® Business Edition, USB/Serial/SNMP (Optional), EPO, Smart Battery Management (SBM), Extended Battery Available

Rp82,477,000

UPS 3Ph-400VAC/1Ph-230VAC input, 1Ph 230VAC Output, LCD Control Panel, Tower Model, 20000VA/18000W, Double Conversion Online, 1 x hardwire terminal block outlet, BUT 6 mins @ full-load, Genset Compatible, Surge Protection 445 Joules, PowerPanel® Business Edition, USB/Serial/SNMP (Optional), EPO, Smart Battery Management (SBM), Extended Battery Available

Kategori: Tag: ,
Berat 60 kg
brands

Model Name
OLS3S20KE
General
UPS Topology Double Conversion Online
Energy Saving ECO Mode Efficiency >97%
Energy Star Qualified
Active PFC Compatible Yes
Input
Voltage 220-240Vac (Line to Neutral) / 380 – 415Vac (Line to Line)
Input Voltage Range 176-276Vac (Line to Neutral) / 305-478Vac (Line to Line)
Input Frequency Range 50/60Hz ± 10% (Auto-sensing)
Rated Input current 90.9A
Input Power Factor 0.99
Cold Start Yes
Plug Type
Output
VA 20000
Watt. 18000
On Battery Waveform Sine Wave
On Battery Voltage 208, 220, 230, 240Vac (Configurable)
Automatic Voltage Regulation (AVR)
On Battery Frequency 50/60Hz ± 0.05Hz
Outlets – Total 1
Outlet Type Terminal Block
Outlets – Battery & Surge Protected
Outlets – Surge-Only Protected
Outlets – Widely Spaced
Outlets – Critical Load
Outlets – Non-Critical Load (NCL)
Outlets – ECO Controlled Outlets
USB Charging Ports
Rated Power Factor 0.9
Harmonic Distortion THD < 2% at Linear Load, <5% at Non-linear Load
Transfer Time 0ms
Battery
Runtime at half load (min) 12.8
Runtime at full load (min) 1.5
Battery Type Sealed Lead-Acid
Battery Size 12V/9AH
Battery Quantity 20*2
User Replaceable Yes
Hot-Swappable
Typical Recharge Time 8 hours
Smart Battery Management (SBM) Mode Yes
Extended Battery Module BPSE240V82A
Replacement Battery Pack
Replacement Battery Pack Quantity
Surge Protection & Filtering
Surge Supression 445 Joules
Phone Protection RJ11
Phone / Network Protection RJ11/RJ45
Management & Communications
LCD Control Panel 21 different settings options via UPS Setting menu
Detachable LCD Control Panel Option
HID Compliant USB Port Yes
Serial Port Yes
Emergency Power Off (EPO) Port Yes
Dry Contacts
LED Indicators Yes
Audible Alarms Yes
Software PowerPanel® Business Edition
SNMP / HTTP Remote Monitoring Yes, with optional RMCARD302 / RMCARD303
Physical
Form Factor Tower
Physical – UPS Module
Dimensions (WxHxD) (mm) 350 x 890 x 650
Weight (kg.) 172
Installed Rack Height
Physical – Power Module
Dimensions (WxHxD) (mm)
Weight (kg.)
Power Module Rack Height
Physical – Battery Module
Dimensions (WxHxD) (mm)
Weight (kg.)
Battery Module Rack Height
Environmental
Operating Temperature 32oF to  104oF / 0oC to 40oC
Operating Humidity 0% – 90% non-condensing
Operating Elevation 0 – 3281ft (0-1000 meters)
Storage Temperature 5oF to  113oF / -15oC to 45oC
Storage Relative Humidity 0% to 95% non-condensing
Online Thermal Dissipation 3487 BTU/hr

Based on 0 reviews

0.0 overall
0
0
0
0
0

Only logged in customers who have purchased this product may leave a review.